Description
Fine-Tuning for Integrity: A system with unbalanced currents is an inefficient system. At TECNA ICE, we adjust every parameter to ensure that protection is delivered exactly where it is needed.
Service Description
The adjustment and balancing of cathodic protection systems is a critical step that follows commissioning or is performed during maintenance audits. In complex systems, it is common to encounter “crosstalk” or mutual interference between different current sources (rectifiers). TECNA ICE uses precision instrumentation to measure current draw at each node and adjust the control resistors in the distribution boxes. This process ensures that the current density is uniform throughout the structure, preventing some areas from becoming vulnerable to corrosion while others suffer from overprotection, which could cause hydrogen embrittlement or coating delamination.
Adjustment Activities
- Calibration of Rectifier Outputs.
- Adjusting variable resistors in junction boxes.
- Mitigation of direct current (DC) interference.
- Synchronization of switches for ON/OFF measurements.
Results Obtained
- Balanced and stable potential profiles.
- Reduction of unnecessary energy consumption.
- Extending the service life of anode beds.
- Strict compliance with the NACE SP0169 criteria.
Detailed Engineering
TECNA ICE approaches system balancing not only as an electrical task, but as an electrochemical challenge. We analyze the resistivity of the surrounding environment and the condition of the coating to determine the optimal operating set point. Especially in plants with a high density of buried pipes, our team conducts influence tests to ensure that a system’s current is not damaging a neighboring structure. Upon completion of the service, we provide a detailed report with the new operating parameters and an updated baseline for routine monitoring of the asset.
When Is an Alignment and Balancing Necessary?
Expansions
When new pipelines or tanks are added to the network.
Interference
Detection of unusual potential fluctuations.
Annual Audit
As part of regulatory preventive maintenance.
Post-Construction
Immediately after the initial startup.
Do you feel that your cathodic protection system isn’t performing at 100%?