Coating Thickness Measurement (Dry/Wet)

📏
Micras Control
✅
Dry/Wet Quality
🛡️
Corrosion Protection

Technical inspection of coating thicknesses on industrial coatings. We verify dry and wet film thicknesses in accordance with international standards to ensure maximum durability of the corrosion protection for your assets.

Description

Protection Guarantee: We verify that each coating layer meets the specified micron thickness, preventing premature failure due to corrosion or peeling.

Service Description

Film thickness measurement is a critical non-destructive test in the coatings industry. At TECNA ICE, we perform Wet Film Thickness (WFT) measurements during the application process to allow for immediate corrections, and Dry Film Thickness (DFT) measurements once curing is complete. This control ensures that the coating system provides the necessary protective barrier against the environment, strictly complying with manufacturers’ technical data sheets and international standards such as SSPC or ISO.

Technical Scope

  • DFT measurement on ferrous and non-ferrous substrates.
  • WFT control using precision combs in the field.
  • Inspection of multi-layer systems (Primer, Intermediate, Topcoat).
  • Verification of the anchor profile prior to installation.

Operational Benefits

  • Optimizing paint usage and reducing waste.
  • Prevention of failures caused by excessive or insufficient thickness.
  • Certification of compliance for manufacturer warranties.
  • Full traceability of the quality of the applied coating.

Methodology and Regulations

Our inspectors use properly calibrated and certified electromagnetic and eddy current gauges. We apply methodologies based on the SSPC-PA 2 standard, which defines the number of measurements and acceptance criteria to ensure that the average coating thickness is representative across the entire surface of the asset. Each data point is collected digitally to facilitate the generation of thickness maps and final inspection reports.

Industries Where We Apply This Service

 

Oil & Gas

Protection of tanks and flow lines.

 

Shipowner

Coatings for hulls and decks.

 

Infrastructure

Bridges and heavy steel structures.

 

Energy

Transmission towers and penstocks.

Do you need to certify the quality of your coating?