Description
Cutting-Edge Technology: We have implemented the SpotWave 201 device, a global leader in recording transient waveforms for the detection of minimal acoustic impacts.
Service Description
Acoustic Emission (AE) inspection is a passive Non-Destructive Testing (NDT) technique that allows for the real-time evaluation of the integrity and internal tightness of valves. Unlike conventional hydrostatic tests, our solution identifies internal leaks and pressure losses by analyzing high-frequency acoustic signals, allowing maintenance to be prioritized without removing the component from the process line.
Technical Scope
- Use of specialized sensors (VS150-M and VS30-V) depending on the material.
- Processing of acoustic impacts and waveforms.
- Evaluation of Shut-off, Control, and Safety Valves.
- Diagnosis of metal and concrete structures.
Operational Benefits
- Zero downtime: inspection while the plant is running.
- Early detection of internal leaks.
- Reducing Environmental Risks from Containment Failures.
- Technical traceability in accordance with European standard EN 13477-1.
Methodology and Sensors
At TECNA ICE, we select the right sensor for every challenge: we use the VS150-M to ensure the integrity of metal pressure vessels and the low-frequency VS30-V for large structures or attenuating materials such as concrete. This technical approach ensures that every transient signal is captured and analyzed with pinpoint accuracy, transforming acoustic noise into actionable data for integrity management.
Industries Where We Apply This Service
Oil & Gas
Pumping and transportation stations for hydrocarbons.
Petrochemical
Monitoring of critical valves in continuous processes.
Generation
Thermal and hydroelectric power plants.
Infrastructure
Large-scale systems and attenuating materials.
Do you suspect internal leaks in your critical valves?
Get an accurate diagnosis without interrupting your operations using AE technology.